Tensile shear test on overlapping bonds
Including high-resolution measurement of the shear path
A special feature of this experiment is the additional bonding of an adapter piece to compensate for thickness differences. This experimental setup allows a conventional clamp-on...EXTENSOMETER It is used for the finest adjustment of the adhesive surfaces. It has a measuring resolution of 0,000.1 mm.
In order to make the results comparable, the area of the bond is measured before the test (sample width and length of the overlap). The determined maximum test force is divided by this area to determine a shear stress.
Since the test pieces are relatively stiff, the clamping device must be offset to avoid bending influences on the bonding point. This was achieved by a special clamping device realized. In this case, a center offset of the upper to the lower clamping plane can be achieved by manually adjusting the left clamping surface.