Partial device for marking tensile specimens for manual elongation at break measurement
Surface-friendly marking of critical tensile specimens
Tensile specimens where only a low elongation at break is expected due to the alloy, material, processing condition, or heat treatment are often sensitive to surface damage. Therefore, for manual determination of elongation at break, these specimens should not be marked with deep scratches or impact marks – for example, by falling weight systems. Mechanically introduced notches can cause stress concentrations and thus promote premature fracture. This can affect not only the measured elongation at break but also, potentially, the determined tensile strength. Examples of potentially sensitive materials and specimens include:
- Aluminum die-casting alloys
- Grey cast iron and ductile iron
- high-strength, hard steels, e.g. tensile strength >1.500 MPa
- Tensile test specimens from additive manufacturing
- other brittle or notch-sensitive materials
Technical information
- Tip height: 50 mm
- Distance between clamping tips: up to 200 mm
(without additional sleeves or knurled nuts) - T-slot width: 10 mm
- Base plate dimensions: 350 × 110 mm
- Includes two adjustable riding sticks
- Left tailstock with fixed tip
- Right tailstock with spring-loaded tip, stroke approx. 10 mm
- Riding sticks with eccentric clamping, quickly fixable
- Includes T-slot and measuring stand
- Special versions for marking combs and anti-rotation devices
I SO 6892-1: “If the required minimum value of elongation at break is less than 5%, it is recommended that special precautions be taken when determining the elongation at break (see Annex H)”
Appendix H: “A recommended procedure is described below:
Before the test, a very small mark should be made near both ends of the parallel length. Using a dividing device with needle points spaced according to the gauge length, an arc is drawn with the first mark as its center point. After the fracture, the broken specimen should be placed in a clamping device. By applying an axial compressive force, preferably using a screw, the specimen pieces are pressed firmly together during the measurement. A second arc with the same radius from the original center point, closest to the fracture, should be drawn. The distance between the two marks is measured with a measuring microscope or other suitable instrument. To make the fine marks more visible, a suitable coating of dye may be applied to the specimen before the test.
Video Rotation Marking System
Marking by selectively removing a layer of paint
We have developed a special marking system for sensitive tensile test specimens. Before marking, a thin layer of marking ink or the ink from a permanent marker is applied to the specimen surface. The marking comb then removes the ink layer with fine tips precisely at the designated measuring points.
The resulting color contrast makes the measurement marks clearly visible without creating notches in the sample surface. After the tensile test, the marks can be reliably measured and evaluated using calipers – with the aid of a magnifying glass if necessary.
Precise and efficient marking
The dividing head enables the efficient marking of tensile specimens with a uniform and precise division. The standard marking grid is 5 mm. Other metric divisions and marking grids for ASTM tests are available upon request. The length of the marking area is designed according to the required initial gauge length L₀ and the specific test requirements. If necessary, the marking can extend over a large portion of the parallel length Lc. However, the entire marked area, including the outer markings, must lie within the parallel area of the tensile specimen and must not extend into the transition radii.
If the applicable testing standard and the specified sample geometry permit, Lc can be made slightly longer during mechanical sample preparation. Depending on the design, for example, an extension of approximately 2 mm may be useful to ensure that the outer tips of the marking comb are securely positioned within the parallel sample area. Alternatively, the outer graduation marks on the marking comb can be omitted.
The marking combs can be easily and quickly replaced using locking pins. This allows the dividing head to be adapted to different initial gauge lengths L₀, marking lengths, and division grids.
Hardened, precision marking comb
The marking comb is hardened to approximately 60 HRC and features precisely machined, sharp-edged tips produced using EDM. The contact pressure is applied manually by light and controlled pressure. This allows for very precise adjustment of the force to the specific sample surface. With hard, previously stained samples, marking can be performed in such a way that only the stain layer is removed, without creating any notches in the sample surface.
Direct scribing of the sample surface is also possible. However, this should be avoided with brittle, notch-sensitive, or only slightly deformable materials unless an influence on the fracture behavior can be reliably ruled out.
Quick and centered clamping of the tensile test specimen
The tensile test specimen is clamped between two center points. The centering bores already machined on the lathe during production can be used for this purpose. One of the center points is spring-mounted, ensuring secure positioning of the specimen. If a centering bore is missing, it can be replaced – as shown in the video – by a specially designed knurled screw. Suitable end sleeves with a centering bore are available for tensile test specimens with cylindrical heads.
Alternatively, the device can be equipped with a quick-release chuck. Special mounts for other sample and head shapes are available upon request.
