Used hardness testers

Used Brinell and Vickers testers

Refurbished devices including warranty and DAkkS calibration

Note: The photos of the Brinell/Vickers testers shown are examples of used equipment. We strive to keep these in stock at all times. However, we must check whether the desired machine is available in each individual case. Therefore, we regret to inform you that the item is subject to prior sale.

Note: All suppliers of dial gauges for Rockwell hardness testing have discontinued production. Therefore, we are no longer able to offer a universal testing device that includes all three methods (including Rockwell). We modify these devices so that only the Vickers and Brinell methods are available. For Rockwell hardness testing, please select a simple Rockwell hardness tester.

Interested? Contact us now!

Contact us for currently available used hardness testers

WOLPERT Dia-Testor: 2n for Vickers + Brinell
 

Brinell tester Vickers tester WOLPERT Dia-Testor 2n

WOLPERT Brinell/Vickers hardness testers are the top choice among used equipment. Unlike current WOLPERT hardness testers (which are now manufactured exclusively in China), the purely mechanical devices offered here represent precision engineering made in Germany. These machines are extremely reliable and, should a defect occur, can be repaired by our qualified service team at minimal cost. Upgrading these devices also enables more efficient operation and fulfills documentation requirements, including the printing of test certificates.

Technical information

Production

WOLPERT

Type

Dia-Testor 2n (1-lever device)

test load levels

Vickers
Brinell
no longer available: Rockwell

( 1 | 2 | 3 *) 5 | 10 | 20 | 30 | 40 | 50
15,625 - 31,25 - 62,5 - 125 - 187,5 - 250

test room height / depth

300 / 130 mm

dimensions (H/W/D)

937 / 350 / mm 612

Weight

approx. 210 (kg)

Condition

used, workshop overhauled, including warranty

Painting

mostly good original paint / repainting optional

Delivery

Machine body with integrated loading device, optical measuring device with 1 lens (20 or 44 or 70 or 140x magnification) and corresponding scale, clamping cap, indenter of choice (Vickers and/or Brinell) with DKD/DAkkS test certificate, support table Ø 80 mm, threaded spindle with handwheel, oil damping for shock-free loading.

options

– Indenter Vickers 136° pyramid with DKD – test certificate
– Indenter carbide ball with ball holder Brinell Ø 2,5 mm

Option: Modernization

– SHP150 electronic scale, foot switch, HardworX software

* The load levels marked above for Vickers are only conditionally DKD/DAkkS calibratable, as a 200x or 400x lens is not available from the manufacturer/supplier! The load levels are conveniently set using the load selection pushbuttons. The machine comes standard with a conventional optical measuring device in which the generated Vickers or Brinell impression is projected onto the ground glass screen via a lens and vertical illuminator (semi-transparent deflecting mirror). Evaluation is performed by measuring the impression diagonals using the included scale (ruler). Option: Digital scale for evaluation using HardworX software


Small-force Vickers tester ZWICK – Z3212

ZWICK 3212 with eyepiece measuring device: Optional camera measuring system

Conventional Vickers load tester for load classes HV 0,2 to 10 kg, good original paint finish. The different load classes are set by placing different weights on the tester. Conventional optical measuring device (measuring microscope) with integrated scale (vernier scale). Special feature : The integrated measuring turret (up to four lenses) allows for quick magnification changes.

HV – levels

0,2 | 0,3 | 0,5 | 1 | 2 | 5 | 10

test room

Height 300 mm – without cross table

Disinvitation

135 mm

Size

300 | 400 | 500 mm

Weight

Approx. 55 kg

power connection

230 / 50 V/Hz

Delivery

Base frame with base plate and integrated electronics, column and support arm, load device with adjustable oil damping for the shock-free application of the test load, measuring optics (precision measuring microscope), coarse test height adjustment
– with clamping wheel + fine drive, Vickers indenter diamond pyramid 136° with DKD / DAkkS – calibration certificate, one lens, without cross table

options

– Cross table (new) division 10µ
– Binocular view
– Revolver for up to 4 measuring optics
– new lenses 100x / 200x / 400x / 600x
CMS camera measuring system with HardworX hardness testing software


Small-force Vickers tester FRANK – Finotest

FRANK FINOTEST eyepiece measuring device, optional camera measuring system

Conventional testing device for Vickers hardness tests : good original light grey paint, the different load levels are set by placing different weight levels on the surface, conventional optical measuring device (measuring microscope) with integrated vernier scale.

HV – levels

0,2 | 0,3 | 0,5 | 1 | 2 | 5 | 10

test room

Height 295 mm – without cross table

Disinvitation

135 mm

Size

680 / 290 / mm 380

Weight

Approx. 50 kg

power connection

230 / 50 V/Hz- (integrated transformer): 8 V / 0,15 A (0,2 A)

Delivery

Base frame with base plate, column and holding arm, loading device with adjustable oil damping for shock-free application of the test load, evaluation optics (precision measuring microscope), coarse test height adjustment (clamping wheel) + fine drive, one lens, Vickers indenter 136° with DKD / DAkkS test certificate, without cross table

options

– Cross table (new part) with 10µ pitch
– Binocular view
– Revolver for multiple measuring optics
– new lenses 100x / 200x / 400x / 600x
– CMS camera measuring system with HardworX hardness testing software


WOLPERT – Dia-Testor 3b modern stand-alone device 3000 kgf

Brinell testing device WOLPERT Dia-Testor 3b

Conventional testing machine for hardness tests according to Brinell for load levels (kgf): 187,5 / 250 / 500 / 750 / 1000 / 1500 / 2000 / 2500 / 3000. The different load levels are easily adjusted by inserting bolts or removing individual weights. Conventional optical measuring device with projection onto the screen and measurement using a scale (ruler).

test room height / depth

400 / 210 mm

dimensions (H/W/D)

approx. 1.800 / 750 / 1100 mm (including base cabinet)

Weight

Approx. 440 kg

power connection

400 / 50 V/Hz

Delivery

Machine body with integrated loading device, complete optical device with 1 lens (20 or 44 or 70 times magnification) and corresponding scale, clamping cap, 1 indenter, support table Ø 80 mm, threaded spindle with handwheel, oil damping for shock-free loading.

options

– Hard metal ball with holder Brinell Ø 2,5 mm
– Hard metal ball with holder Brinell Ø 5,0 mm
– Hard metal ball with holder Brinell Ø 10,0 mm
– large support table 400 x 600 mm
– additional lenses 20x, 44x, 70x or 140x
– Vertical illuminator (for lenses 44, 70, 140x)
– Hardness comparison plates with DKD calibration certificate

Option: Modernization

– SHP150 electronic scale, probe, HardworX software


Inquire about used Vickers testers or Brinell testers now

E-mail Phone